  Datasheet File OCR Text:
  the copyright and authority for the interpretation of the products are reserved by mornsun tsx01-ex 2013.07.01-a/4 page 1 of 3 isolating / safety switching barrier (transistor output) tsx01-ex series part number system TS201-EX safety barrier mark transistor output signal style product seriers channel number features fitted devices: 1. namur sensors; 2. mechanical joints. phase-angel and inverse control setting; open circuit detection setting operation temperature:-25 c to +71 c reliable performance (mtbf>1,000,000 hours) general description this isolation switching barrier can detect switch or approach switch s status in locations where hazardous exists; isolate, transmit and output it to safe area. input and output can be set to inverse control. approach switch open circuit detection function. isolation between input/ output/power source. product program input(power) output(hazardous end) voltage(vdc) voltage part number typ. range typ. short circuit current output (safe end) channel numbers ts101 1 ts201 2 ts101-ex 1 TS201-EX 24 18-36 8vdc about 8 ma transistor output 2 electrical specifications operation voltage 18-36vdc input frequency about 2.4w common parameter power indicating led light (green) on when operating input signal switch status of namur sensor, mechanical joint etc distribution voltage about 8v (open status) short circuit current about 8ma input switching frequency 5khz open circuit threshold current 0.1ma hazardous area switching threshold typ:1.55ma (hysteresis:0.2ma) output signal transistor output (passive pulse) external source 40vdc driving capability 40ma(build-in short circuit protection) transistor collector high level: vcc ; low level: 2.5vdc safe area transistor emitter high level: vcc-2.5v ; low level: 0.5vdc transmission specifications input loop current > 2.1ma, transistor output open, channel indicator light (red) on. under phase-angel control (k2 k3 off ) input loop current < 1.2ma, transistor output close, channel indicator light (red) off. input loop current > 2.1ma, transistor output close, channel indicator light (red) off. under inverse control (k2 k3 on ) input loop current < 1.2ma, transistor output open, channel indicator light (red) on. when connected with namur sensor input loop current < 0.05ma, open circuit alarm, channel red indicator light (yellow) on. when connected with common contact joint switch to achieve open circuit detection function, a 10k resistor must be connected to the switch in parallel. note: k2 is setup channel1 to be reverse or not ,k3 is setup channel2 to be reverse or not.
the copyright and authority for the interpretation of the products are reserved by mornsun tsx01-ex 2013.07.01-a/4 page 2 of 3 isolation specifications five-port isolation output ~ input: 2.5kvac power supply ~ input: 2.5kvac power supply ~ output: 1.5kvac output 1 ~ output 2: 1.5kvac input 1 ~ input 2: 1.5vac electrical isolation three-port isolation (single channel); five-port isolation(dual channels) isolation strength 2.5kvac (test for 1minute, humidity < 70%) emc en61326 standards & certificates explosion protection certificate mark [exia]iic explosion protection certificate parameters between the pin 11 and 12: um=250vac/dc uo=10.5vdc io=5.3ma po=14mw co=1.68 f lo=1000mh explosion protection certificate agency china national quality supervision and test centre for explosion protected electrical products explosion qualified no. cnex08.0003 other specifications operation temperature:-25 c ~ +71 c ambient temperature transport and storage temperature:-50 c ~ +105 c mounting 35mm din-rail package, hot plug, thickness: 22.5mm, plastic ul94-v0 safety grade ip20(iec60529 / en60529) weight about 128g connection i n intrinsic safety explosion protection systems, isolating barrier belongs to affiliated device. it is installed at safe area, as a connection between intrinsic safety devices in the hazardous area and non-intrinsic safety devices in the safe area. by limiting the energy to a certain safe amount, it ensures the safety of in spot devices and people. selection regulations for intrinsic safety explosion protection system: 1 the explosion protection grade of the barrier must be equal to or higher than that of in spot intrinsic safety explosion protection device. 2 take inconsideration of hazardous end output resistance and loop resistance, ake sure the barrier s output voltage meets the minimum operation voltage requirement of in spot intrinsic safety device. 3 the safety parameters of barrier s intrinsic safety end meets: uo ui, io iin, po pin co cin, lo lin 4 select suitable safety barrier which matches the in spot intrinsic safety device for the power s phase, signal type and transmission mode. 5 apply necessary protections, avoid influence the in spot intrinsic safety device s operation from leakage current that generated by safety barrier. operation notes: 1. please read the user manual carefully before using. if any questions please contact our technical support department. 2. please do not use this product in hazardous area. 3. the power supply of this product should be 24vdc power source. it is forbidden to use 220vac power supply. 4. to avoid invalid explosion protection function, or any failure, users disassemble this product is forbidden. application circuit diagram & pin description 5 power 6 16 15 8 7 safe area hazardous area 12 11 4 3 channel1 channel2 dcs plc note:in single model channel2 is invaid transistor output mode and connections (safe area): passive pulse rl=220k vcc vcc transistor collector output transistor emitter output passive pulse rl=220k
the copyright and authority for the interpretation of the products are reserved by mornsun tsx01-ex 2013.07.01-a/4 page 3 of 3 installation & disassembly installation din35mm standard rail installation: 1.insert the top of the instrument card in the rail; 2.push the bottom of the instrument into the rail. disassembly 1. use a screwdriver (width of edge 6mm), cut in the metal card lock from the underside; 2. boost up the screwdriver and pry the metal card lock downwards; 3. pull the instrument out of the rail. 1 2 3 packaging dimension & packaging diagram note: 1. all specifications are measured at ta=25 c, humidity<75%, nominal input voltage and rated output load unless otherwise specified. 2. in this datasheet, all the test setup and methods are based on our corporate standards. 3. all characteristics are for listed models, and non-standard models may perform differently. please contact our technical support for more details. 4. please contact our technical support for any specific requirement. 5. specifications of this product are subject to changes without prior notice. mornsun science & technology co.,ltd. address: no. 5, kehui st. 1, kehui development center, science ave., guangzhou science city, luogang district, guangzhou,p.r.china. tel: 86-20-38601850 fax:86-20-38601272 e-mail: info@mornsun.cn http://www.mornsun-power.com


▲Up To Search▲   

 
Price & Availability of TS201-EX

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X